| Check | Expected condition | Result |
|---|---|---|
| Input source | stable 208/230 V class branch, ideally 50 A for full-capacity proof | pass / fail |
| Generator path if used | meets or exceeds the official 5 kW baseline | pass / fail |
| Clamp and holder | clean bite, tight Dinse fit, no obvious heat damage | pass / fail |
| Extension cord or adapter path | not undersized or overheated | pass / fail |
| Rod condition | dry 7018 or 6010/6011 class rod matched to baseline and top-end proof | pass / fail |
| Lead polarity | holder and ground leads placed correctly for the actual rod test because A220 can run DCEN or DCEP | pass / fail |
| Checkpoint | Expected value or behavior | Record actual |
|---|---|---|
| Input supply at machine | stable 208/230 V class input under attempted load | |
| OCV at output studs | about 74 V class OCV | |
| Clamp or holder temperature under load | no rapid abnormal heating | |
| Top-end arc feel | strong, stable field-inverter behavior when fed correctly | |
| Yellow protection light at higher load | stays off in normal short heavy proof welding | |
| Stock holder and clamp path | 5 ft AWG #4 lead set stays electrically stable without fast abnormal heat |
| Test | Pass condition | Result |
|---|---|---|
| Cold power-up | normal idle state with no odd collapse | pass / fail |
| Short stick strike | repeatable strike on clean steel | pass / fail |
| Short weld | stable arc with no abnormal clamp or holder heating | pass / fail |
| Higher-load retest | top-end behavior remains stable on a true 230 V or healthy generator source using 7018 or 6010/6011 proof rod | pass / fail |
| Polarity sanity retest if arc is wrong | wrong-feel complaint disappears once lead placement matches the rod test | pass / fail |
KAA20410: official product page07000460: official product page07000461: official product page| Signoff item | Result |
|---|---|
| OCV restored | pass / fail |
| High-load rod baseline restored | pass / fail |
| Short weld completed cleanly | pass / fail |
| No abnormal heating, protection light, or source-path collapse after retest | pass / fail |
Technician: __________ Date: __________ Serial or shop tag: __________