Bench Test / KickingHorse / A220

Test intent

Tools and setup

Pre-power checks

Check Expected condition Result
Input source stable 208/230 V class branch, ideally 50 A for full-capacity proof pass / fail
Generator path if used meets or exceeds the official 5 kW baseline pass / fail
Clamp and holder clean bite, tight Dinse fit, no obvious heat damage pass / fail
Extension cord or adapter path not undersized or overheated pass / fail
Rod condition dry 7018 or 6010/6011 class rod matched to baseline and top-end proof pass / fail
Lead polarity holder and ground leads placed correctly for the actual rod test because A220 can run DCEN or DCEP pass / fail

Electrical checkpoints

Checkpoint Expected value or behavior Record actual
Input supply at machine stable 208/230 V class input under attempted load
OCV at output studs about 74 V class OCV
Clamp or holder temperature under load no rapid abnormal heating
Top-end arc feel strong, stable field-inverter behavior when fed correctly
Yellow protection light at higher load stays off in normal short heavy proof welding
Stock holder and clamp path 5 ft AWG #4 lead set stays electrically stable without fast abnormal heat

Functional proof

Test Pass condition Result
Cold power-up normal idle state with no odd collapse pass / fail
Short stick strike repeatable strike on clean steel pass / fail
Short weld stable arc with no abnormal clamp or holder heating pass / fail
Higher-load retest top-end behavior remains stable on a true 230 V or healthy generator source using 7018 or 6010/6011 proof rod pass / fail
Polarity sanity retest if arc is wrong wrong-feel complaint disappears once lead placement matches the rod test pass / fail

If it fails

Direct official parts pages

Post-repair release

Signoff item Result
OCV restored pass / fail
High-load rod baseline restored pass / fail
Short weld completed cleanly pass / fail
No abnormal heating, protection light, or source-path collapse after retest pass / fail

Technician: __________ Date: __________ Serial or shop tag: __________