0.035 in flux-core baseline wire plus proper 0.030 in conversion hardware only if that branch is being tested3 kW generator baseline only if the complaint specifically involves portable power| Check | Expected condition | Result |
|---|---|---|
| Torch front-end assembly | left-hand-thread seat and right-hand-thread tip assembled correctly | pass / fail |
| Wire path baseline | free feed with tip removed on the factory 0.035 in setup or a proper 0.030 in conversion only |
pass / fail |
| Clamp and current path | tight and clean | pass / fail |
| Input source | real 120 V / 20 A branch or stable 3 kW generator path with no hot adapter or non-compliant cord |
pass / fail |
| Unsupported setup check | no 0.023 in wire and no wire that requires DCEP |
pass / fail |
| Checkpoint | Expected value or behavior | Record actual |
|---|---|---|
| Trigger-state voltage before trigger | about 12 VDC class low-state value |
|
| Trigger-state voltage after trigger | rises into about 44 VDC working-state range |
|
| OCV baseline | about the official 46 V class baseline |
|
| Feed behavior at idle | stopped until trigger command | |
| Arc behavior with fresh front-end | stable enough to prove the machine before deeper repair on correct 0.035 in baseline |
|
| Protection light behavior | stays off during a short proof weld on the correct source baseline |
| Test | Pass condition | Result |
|---|---|---|
| Stable startup | no immediate breaker trip or abnormal idle state | pass / fail |
| Trigger feed | feed starts on command and stops cleanly | pass / fail |
| Short FCAW proof weld | stable weld with no severe stubbing or front-end flare on the correct 0.035 in baseline |
pass / fail |
Optional 0.030 in retest |
only if conversion hardware is correct; no new fault created by proper conversion | pass / fail / n-a |
| Warm restart | no repeat trip, protection-light event, or sudden loss of feed | pass / fail |
0.035 in baseline or after a proper 0.030 in conversion: stop before deeper electrical repair.0.023 in or requires DCEP: stop and correct setup before electrical escalation.KOM32135: official product page| Signoff item | Result |
|---|---|
| Stable startup restored | pass / fail |
| Trigger-state split behaves normally | pass / fail |
0.035 in baseline or correct 0.030 in converted baseline restored |
pass / fail |
| No repeat trip, severe stubbing, protection-light event, or front-end complaint after power cycle | pass / fail |
| Correct source baseline documented on release ticket | pass / fail |
Technician: __________ Date: __________ Serial or shop tag: __________