Bench Test / KickingHorse / M185

Test intent

Tools and setup

Pre-power checks

Check Expected condition Result
Torch, liner, and tip baseline clean and matched to wire size pass / fail
Clamp and lead path tight and clean pass / fail
Display window and panel controls intact and readable after service pass / fail
Wire path baseline free movement with tip removed pass / fail
Source path baseline correct 208/230 V supply with breaker path matched to the intended proof level pass / fail
Inductance baseline returned to a sane known-good starting point before blame is placed on the machine pass / fail

Electrical and control checkpoints

Checkpoint Expected value or behavior Record actual
Display on startup stable and readable, not locked or obviously wrong
OCV baseline about the official 72 V class OCV
Feed at idle stopped until trigger command
Display response arc-off to arc-on preset values at idle, then actual values during weld rather than staying frozen
Inductance reset retest starts improve or stay stable after returning inductance to sane baseline
No-feed plus bad display treated as one electrical branch until proven otherwise
Protection light behavior stays off during short proof weld on a correct source baseline

Functional proof

Test Pass condition Result
Stable startup no abnormal display state pass / fail
Trigger feed feed starts on command and stops cleanly pass / fail
Short MIG weld stable weld with sensible display response after source and inductance baseline are normalized pass / fail
Warm restart no return of frozen display, no-feed condition, or protection-light complaint pass / fail

If it fails

Direct official parts pages

Post-repair release

Signoff item Result
Stable startup restored pass / fail
Display behavior restored pass / fail
Base MIG baseline restored on correct 208/230 V source and sane inductance setting pass / fail
No repeat no-feed, frozen-display, or source-path collapse complaint after power cycle pass / fail
Preset-to-actual display transition confirmed on release weld pass / fail

Technician: __________ Date: __________ Serial or shop tag: __________