Bench Test / WeldKing / CoolCut40air

Test intent

Tools and setup

Pre-power checks

Check Expected condition Result
Torch front-end stack correctly assembled, fresh SG55 consumables pass / fail
Clamp placement bright metal, tight return path pass / fail
Internal-air package water trap drained and internal compressor path unobstructed pass / fail
External-air path if used dry air and stable pressure under flow pass / fail

Electrical checkpoints

Checkpoint Expected value or behavior Record actual
Internal-air trigger test air should follow the intended internal path only
External-air trigger test external path should not be held open incorrectly
Dual-air behavior both paths should not flow together unless the fault is present
Start behavior repeatable pilot and transfer on clean steel

Functional proof

Test Pass condition Result
Internal-mode retest stable internal air delivery and clean start pass / fail
External-mode retest stable external air delivery and clean start pass / fail
Short cut stable cut without dropout or moisture-related sputter pass / fail
Warm retest no return of dual-air or valve confusion after several starts pass / fail

If it fails

Direct official parts pages

Post-repair release

Signoff item Result
Internal-air mode restored pass / fail
External-air mode restored if used pass / fail
Stable start and cut restored pass / fail
No dual-air or contamination behavior remains pass / fail
No abnormal valve or moisture behavior after retest pass / fail

Technician: __________ Date: __________ Serial or shop tag: __________