| Check | Expected condition | Result |
|---|---|---|
| Machine version path | HF and no-HF assumptions match the fitted unit | pass / fail |
| Torch front end | fresh, correctly assembled, no obvious gas leak path | pass / fail |
| Gas setup | stable argon flow with no hose or regulator leak | pass / fail |
| Control branch | only the intended torch-switch, remote, or pedal path connected | pass / fail |
| Baseline state | simple DC TIG with pulse minimized before advanced proving | pass / fail |
| Checkpoint | Expected value or behavior | Record actual |
|---|---|---|
| DC TIG baseline | repeatable starts on clean steel | |
| Gas-flow sequence | stable preflow and postflow | |
| Torch-switch or remote branch | responds only when the correct branch is active | |
| HF or no-HF version path | fitted machine behavior matches the local version note | |
| Stick baseline if used | stable stick output after TIG baseline proves healthy |
| Test | Pass condition | Result |
|---|---|---|
| Cold power-up | normal idle state, no abnormal fan or panel behavior | pass / fail |
| DC TIG start | repeatable start with healthy gas coverage | pass / fail |
| Pulse TIG retest | symptom does not appear only when pulse is added back | pass / fail |
| Stick retest | stick branch works if that branch is part of the complaint | pass / fail |
| Re-power retest | no return of abnormal remote or version-state behavior | pass / fail |
WAT31100: official product page07002510: official product page07000510: use the official CoolTIG220 parts path above.| Signoff item | Result |
|---|---|
| DC TIG baseline restored | pass / fail |
| Version path and active control branch confirmed | pass / fail |
| Pulse or stick branch restored if required | pass / fail |
| Gas path proven stable | pass / fail |
| No abnormal version or remote-state confusion after power cycle | pass / fail |
Technician: __________ Date: __________ Serial or shop tag: __________