Symptom Most likely causes First checks
No HF or no TIG start Torch switch/remote issue, gas path fault, wrong mode Verify remote input, torch switch, mode selection
Stick works but TIG does not Gas/torch/remote issue, not main inverter failure Prove stick output first, then isolate TIG circuit path
AC aluminum weld is poor Wrong balance/frequency setup, gas contamination, torch issue Reset known baseline, inspect tungsten and gas
Random fault/shutdown Cooling restriction, line issue, internal inverter fault Inspect airflow, input quality, and fault behavior

Failure patterns and repair logic

1. No power / dead machine

  1. Verify input voltage, phase, and line setup.
  2. Inspect plug/disconnect, input lugs, and cooling path.
  3. Escalate if the power source remains dead on verified installation.

2. Powers up but no welding output

  1. Prove the simplest process first, usually stick.
  2. If stick output is normal, keep the diagnosis in the TIG accessories and control path until proven otherwise.
  3. If output is absent across all processes, escalate core inverter diagnosis.

3. Feed, arc-start, or cut-start problem

  1. For TIG start issues, check remote mode, torch switch, pedal, and gas flow before blaming HF/current-start circuitry.
  2. For wire-process configurations, isolate the feeder package and control lead.
  3. If only one process family fails, stay in that subsystem.

4. Poor arc quality / unstable output

  1. Reset to a conservative baseline and use clean tungsten and verified gas.
  2. Inspect work return, torch connections, and cooler flow if water-cooled.
  3. Arc instability across AC and DC modes with known-good peripherals is an escalation point.

5. Gas and consumable related faults

  1. Verify regulator, hose, torch body, and gas-lens/nozzle condition.
  2. Replace contaminated tungsten and check collet/collet-body fit.
  3. Porosity, tungsten overheating, and erratic starts are commonly front-end or gas issues first.

6. Intermittent or heat-related behavior

  1. Check fan behavior, airflow blockage, and cooler performance.
  2. Watch for faults after sustained AC welding, where heat load is highest.
  3. Repeated hot-run faults with verified installation and peripherals removed should be escalated.

Fault-code and control-panel clues