This annex is for Lincoln models where the complaint often comes from a mismatch between:
| Machine family | Common false fault | First control-mode check | If corrected behavior returns | If behavior stays abnormal |
|---|---|---|---|---|
| Aspect 230 AC/DC | pedal connected while torch-switch or panel mode is active | verify expected remote method for active TIG mode | keep diagnosis on mode mismatch or settings drift | continue into gas, clamp, tungsten, then base machine |
| Square Wave TIG 200 | remote mismatch or AC settings carried over | reset to simple baseline and verify pedal or torch-switch mode | keep diagnosis on settings and remote path | continue into gas, clamp, and output path |
| Precision TIG 225 | HF or TIG start complaint caused by remote or gas-side issue | verify pedal connection, gas path, and torch arrangement | keep diagnosis on remote, gas, torch, or HF chain | continue into start circuitry only after external path passes |
| POWER MIG 210 MP / 215 MPi | process-change complaint caused by lead placement or optional TIG path assumptions | verify process selection, output-lead placement, and connected accessory | keep diagnosis on process-change setup | continue into actual process branch only after setup passes |
| POWER MIG 211i / 260 | weak or unstable arc misread as control issue | verify branch voltage, gun path, and current path under load | keep diagnosis on gun, gas, or supply | continue into internal fault only after load path is clean |
Do not assume the machine follows the connected device automatically.
basic DC or stick baseline, AC-parameter layer, remote or cooler integration.simple baseline, remote path, advanced AC settings.remote and gas path, HF and start branch, core output.process selection, lead placement, accessory path.