This annex is for one of the highest-frequency false diagnoses in the library: blaming the plasma cutter when the real problem is air quality, inlet pressure, or air delivery under flow.
Use it with plasma guides in this library from:
Static regulator pressure is not enough. Diagnose plasma air under flow.
| Symptom | Most likely air-side branch | High-value first test |
|---|---|---|
| No pilot or no start | inadequate pressure under flow, clamp, torch cap or cartridge seating | verify flow pressure, clamp, and front-end setup |
| Pilot okay, poor transfer | clamp or coated workpiece, borderline air delivery | move clamp and verify airflow under load |
| Poor cut quality | wet air, worn consumables, too much speed | replace parts and retest with dry air |
| Short consumable life | wet air, oily air, poor pierce technique | correct air quality and technique before escalation |
| Intermittent faults after several minutes | compressor capacity, heat in hose path, pressure collapse | reproduce hot and watch air performance under flow |
If the complaint disappears, stop there.