| Checkpoint | Healthy expectation | Diagnostic meaning if abnormal |
|---|---|---|
| Torch polarity for HF start | torch on negative for TIG start | wrong polarity can create a complete no-HF complaint without any failed board |
| Display PCB switch number 2 on later machines | restores factory defaults when flipped with power off and the machine then restarted | if panel corruption clears after reset, the failure was stored-state or display-state related rather than a damaged output stage |
| Gas flow at very low current | moderate flow with preflow reduced as needed for small-current work | excess gas flow can prevent low-current HF starts and should not be mistaken for a dead HF section |
| AC versus DC TIG branch | both operate once the base machine is healthy | DC TIG healthy with no AC keeps the fault in the AC inverter section |
| Symptom | Most likely causes | First checks |
|---|---|---|
| No TIG start | gas path, torch path, or remote mismatch | simplify to DC TIG steel with basic settings |
| AC unstable | settings, tungsten, or dirty material | reset the AC baseline and retest |
| Stick works but TIG does not | TIG branch only | prove stick first and isolate the TIG branch |
| Intermittent fault | heat, remote, or utility path | remove optional controls and retest |
WAT31100 for the torch branch, WAT32106 or WAT32108 for the switch and remote-current branch, 07002510 for the wired pedal branch, and 07002515 for the wireless pedal branch.| Item or assembly | Where it affects diagnosis | Why technicians should check it early |
|---|---|---|
WAT31100 PRO17 TIG gun with on/off switch |
basic HF-start, gas, and torch-switch complaints | this is the simplest official torch branch to prove before moving to remotes or wireless controls |
WAT32106 switch plus remote-current kit and WAT32108 3-button kit |
remote-current and panel-vs-remote complaints | PulseWave200 has multiple control branches, so the active switch module must be proven cleanly |
07002510 FC25-HD wired pedal and 07002515 FC25-WL wireless pedal |
remote-control mismatch and current-control complaints | a clean pedal swap separates remote hardware from control-board faults quickly |
| Argon regulator / flow gauge and TIG accessory kit | porosity, no-HF at low current, and front-end setup complaints | gas-flow and front-end state remain the first false-fault branch on compact TIG systems |
PulseWave200 sheet in troubleshoot_notes.xlsx for the restore-default switch behavior, torch-negative rule, and low-current gas-flow caution before splitting boards.WAT32106, WAT32108, 07002510, and 07002515 when a complaint changes with pedal, switch, or remote hardware rather than panel settings.| Symptom or complaint | First reference to open | Why that reference is the best starting point |
|---|---|---|
| Panel control works but pedal or torch-current control does not | official WAT32106, WAT32108, 07002510, and 07002515 references first |
those are the quickest way to prove whether the complaint follows the control accessory branch rather than the machine |
| All 8s on the display or all lights on after striking an arc | PulseWave200 workbook sheet first |
it documents the restore-default path and keeps a state fault from being misread as hardware failure |
| No HF start | PulseWave200 workbook sheet and owner manual setup section |
the workbook gives the torch-negative and gas-flow split before any board suspicion |
| TIG DC works but AC does not | PulseWave200 workbook sheet |
it directly identifies the AC inverter branch |
| Low-current TIG start unstable | PulseWave200 workbook sheet |
that is the fastest route to the model-specific gas-flow and reset-state cautions |
WAT31100 https://kickinghorsewelders.ca/index.php?main_page=product_info&products_id=47007002510 https://kickinghorsewelders.ca/index.php?main_page=product_info&products_id=33307002515 https://kickinghorsewelders.ca/index.php?main_page=product_info&products_id=367PulseWave200 in assets/reference_doc/all_models/troubleshoot_notes.xlsxPulseWave200 owner manual (.pdf)