| Check | Expected condition | Result |
|---|---|---|
| Torch front-end stack | correctly assembled, fresh consumables, no burned head | pass / fail |
| Clamp placement | bright metal, tight return path | pass / fail |
| Air quality | dry air and stable pressure under flow | pass / fail |
| HF gap before energizing | near the documented 1 mm branch note | pass / fail |
| Checkpoint | Expected value or behavior | Record actual |
|---|---|---|
| Upper-board green 24 V indicator | stays on continuously when 24 V is healthy | |
| Fan behavior | stable, no abnormal collapse when upper-board feed is tested | |
| OCV behavior at start attempt | clearly high, low, or absent and repeatable | |
| HF behavior | visible or audible consistent HF on start attempt |
| Test | Pass condition | Result |
|---|---|---|
| Air sequence | normal preflow and postflow | pass / fail |
| Start test | repeatable HF and start on clean steel | pass / fail |
| Transfer test | transfers cleanly from pilot to cutting arc | pass / fail |
| Short cut | stable cut without dropout | pass / fail |
| Warm retest | no self-switching or support collapse after several starts | pass / fail |
07Y2517003: official product page07Y2517005: official product page07Y2517004: official product page| Signoff item | Result |
|---|---|
| Green 24 V indicator stays steady through start attempts | pass / fail |
| Stable start restored | pass / fail |
| Stable transfer restored | pass / fail |
| Short cut completed cleanly | pass / fail |
| No abnormal 24 V or fan drift after retest | pass / fail |
Technician: __________ Date: __________ Serial or shop tag: __________