Bench Test / WeldKing / MultiSonic220

Test intent

Tools and setup

Pre-power checks

Check Expected condition Result
Polarity connector tight and correct for active process pass / fail
2T or 4T state normal startup expectation confirmed pass / fail
Ribbon and panel seating after service no loose panel-side connectors pass / fail
Wire path baseline tip removed and wire path spins free pass / fail

Electrical and control checkpoints

Checkpoint Expected value or behavior Record actual
Panel at startup stable, no all-lights-flashing behavior
Feeder motor at idle stopped until trigger command
Meter response during live test changes with process and output, not pinned or frozen
MIG-only branch with stick or TIG still healthy polarity connector and MIG control branch proveable before shared power section is blamed

Functional proof

Test Pass condition Result
Normal startup no debug trap, no PRO10-style abnormal behavior pass / fail
MIG trigger feed wire feeds only on command and stops cleanly pass / fail
MIG arc test stable short weld with normal feed and display behavior pass / fail
Stick test stick baseline remains healthy pass / fail
TIG test if equipped simple TIG branch works after MIG and stick are proven pass / fail
Re-power stability no full-speed feeder on restart and no self-shutdown pass / fail

If it fails

Direct official parts pages

Post-repair release

Signoff item Result
Process changeover behaves normally pass / fail
MIG baseline restored pass / fail
Secondary process baseline restored pass / fail
No abnormal display or feeder behavior after power cycle pass / fail

Technician: __________ Date: __________ Serial or shop tag: __________