Bench Test / WeldKing / TIG200PACDC

Test intent

Tools and setup

Pre-power checks

Check Expected condition Result
Torch front end fresh, correctly assembled, no obvious leak path pass / fail
Gas setup stable argon flow and healthy hose path pass / fail
Pedal branch if used correct 4K7 resistance family and no damaged cord pass / fail
Mode setup plain DC TIG selected before AC or pulse proving pass / fail

Electrical and control checkpoints

Checkpoint Expected value or behavior Record actual
DC TIG start repeatable start on clean steel
Pedal or remote response current changes only when the pedal branch is active
AC TIG baseline stable AC start and sustain if AC is required
Stick baseline if used healthy stick output after TIG baseline is proven

Functional proof

Test Pass condition Result
Cold power-up normal idle state, no obvious abnormal display or fan behavior pass / fail
DC TIG baseline clean repeatable starts pass / fail
AC TIG retest stable AC behavior once DC is already healthy pass / fail
Pedal retest no complaint tied only to the remote branch pass / fail
Re-power retest no return of abnormal setup-state behavior pass / fail

If it fails

Direct official parts pages

Post-repair release

Signoff item Result
DC TIG baseline restored pass / fail
AC TIG baseline restored if required pass / fail
Correct pedal or remote response proved if required pass / fail
Remote or pedal branch proven healthy if required pass / fail
Gas path stable after retest pass / fail

Technician: __________ Date: __________ Serial or shop tag: __________