This is the fast internal opening map for F130 once the front end, wire path, wire-size setup, and source-quality branches are already bounded.
0.035 in baseline or on a proper 0.030 in conversion only0.023 in wire, DCEP wire expectations, or a non-compliant cord path25 ft and full 20 A baseline| Board or internal group | Open first when... | Key connector or checkpoint | Best local file to open first |
|---|---|---|---|
| Trigger and control branch | before-trigger and after-trigger behavior does not split correctly | about 12 VDC class before trigger and about 44 VDC class after trigger |
F130 workbook sheet |
| Output and current-path branch | feed is normal but the arc still does not behave correctly after front-end and wire-size proving | output path after external branches are clean and 46 V class OCV is not sustained |
B.067RM.600-C.pdf |
| Generation-specific control branch | fitted board family may not match the machine age | post-March-2017 board arrangement | B.067RM.601-D.pdf and F130 workbook sheet |
120 V / 20 A branch or healthy 3 kW generator is proven.25 ft limit and the complaint is still present.0.035 in baseline or a proper 0.030 in conversion.KOM32135: official product page0.035 in baseline or after a proper 0.030 in conversion.