This is the fast internal opening map for CoolArc160 once the external path is already proven clean.
| Board or internal group | Open first when... | Key connector or checkpoint | Best local file to open first |
|---|---|---|---|
| Capacitor PCB / auxiliary-supply board | OCV is low, the fan slows or stops, or the arc dies after a short run | CN101 high-voltage bus and CN108 or CN104 fan supply path |
COOLARC160_Test_instruction.pdf |
| Inverter PCB | bus is healthy but OCV is absent | machine output branch after bus is already proven | COOLARC160_Test_instruction.pdf and the CoolArc160 workbook sheet |
| Fan revision and connector branch | fan behavior is abnormal and the machine may be an early revision | CN104 versus CN108 location and possible reversed polarity on early machines |
troubleshoot_notes.xlsx CoolArc160 sheet |
CN104 and CN108 are not interchangeable assumptions across revisions.07003650: official product page07000461: official product page07000460: official product page