This is the quick live-reading card for the highest-value A220 utility-path, OCV, and current-path splits.

Use This Card When

Prove First

Fast Measurement Card

Checkpoint Where to measure or observe Healthy expectation If abnormal, keep diagnosis in...
Input supply at machine at the machine input under attempted load stable 208/230 V class input utility path
OCV at output studs output studs with the machine healthy about 74 V class OCV output or current-path branch
Clamp, holder, or plug temperature under load live short-weld observation no rapid abnormal heating current path
Top-end arc feel short higher-load proof weld stable field-inverter behavior when fed correctly utility or current-path branch
Yellow protection light at higher load live observation during short heavy proof weld stays off in normal proof welding cooling, fan, or real source-strength branch
Stock holder and clamp path after short proof weld on fitted 5 ft AWG #4 leads stays electrically stable without fast abnormal heat external current path

Official Parts Shortcuts

Stop Rules

Open Next