This is the quick live-reading card for the highest-value M185 display-feedback and no-feed overlap splits.
208/230 V source with the correct breaker path, about 40 A normal or 50 A time-delay for rated-output proof| Checkpoint | Where to measure or observe | Healthy expectation | If abnormal, keep diagnosis in... |
|---|---|---|---|
| Source and breaker baseline | input source and protection path | healthy 208/230 V source with the intended 40 A or 50 A time-delay path for the proof level |
source path |
| Display on startup | front panel at power-up | stable and readable | display or control branch |
| Preset-versus-actual display transition | front panel arc-off versus arc-on | preset values arc-off and actual values arc-on | display-feedback branch |
| Feed at idle | feeder with no trigger | stopped until command | display-control overlap branch |
| Display response during weld | live weld behavior | changes with actual output | display-feedback branch |
| No-feed plus bad display | combined observation | one shared electrical branch until proven otherwise | display or control branch first |
| OCV baseline | output with machine healthy | about the official 72 V class OCV |
output or control branch |
| Inductance-related start feel | short proof starts after returning inductance to sane baseline | starts should not stumble from a bad setting alone | setup or inductance branch before display-board blame |
KAM31003: official product pageKOM32135: official product page40 A or 50 A time-delay baseline for the proof level.