This is the quick live-reading card for the highest-value P40 plasma start and support-supply splits.
65 psi / 4.5 bar minimum air supply under flow, not just static regulator pressure| Checkpoint | Where to measure or observe | Healthy expectation | If abnormal, keep diagnosis in... |
|---|---|---|---|
| Air supply under flow | regulator and airflow during an actual start attempt | about 65 psi / 4.5 bar minimum while flowing |
compressor, regulator, hose, or wet-air branch before electronics |
| HF strike-pole gap | striker gap at the HF section | about 1.5 mm |
gap, striker cleanliness, or torch-start branch before an HF-board call |
| HF PCB supply | support feed to the HF PCB | about 24 VDC |
support-power or control branch before the HF board itself |
| OCV test point | machine output with the HF wire unplugged from the torch-output branch | measured at the correct point so the reading reflects the machine, not the torch branch | wrong test point can create a false no-OCV diagnosis |
| Control or fan supply | low-voltage support branch | stays near 24 V, not sagging toward 14 V or rising toward 48 V |
switch-power branch rather than torch, clamp, or front-end faults |
07Y2517003: official product page07Y2517005: use the official P40 accessories path above.65 psi / 4.5 bar.