P40 Measurement Card

This is the quick live-reading card for the highest-value P40 plasma start and support-supply splits.

Use This Card When

Prove First

Fast Measurement Card

Checkpoint Where to measure or observe Healthy expectation If abnormal, keep diagnosis in...
Air supply under flow regulator and airflow during an actual start attempt about 65 psi / 4.5 bar minimum while flowing compressor, regulator, hose, or wet-air branch before electronics
HF strike-pole gap striker gap at the HF section about 1.5 mm gap, striker cleanliness, or torch-start branch before an HF-board call
HF PCB supply support feed to the HF PCB about 24 VDC support-power or control branch before the HF board itself
OCV test point machine output with the HF wire unplugged from the torch-output branch measured at the correct point so the reading reflects the machine, not the torch branch wrong test point can create a false no-OCV diagnosis
Control or fan supply low-voltage support branch stays near 24 V, not sagging toward 14 V or rising toward 48 V switch-power branch rather than torch, clamp, or front-end faults

Official Parts Shortcuts

Stop Rules

Open Next