This is the quick external-parts substitution card for the highest-value A220 clamp, holder, and utility-path splits.
| Complaint branch | Swap first | If the complaint follows the part... | If the complaint stays with the machine... |
|---|---|---|---|
| poor rod behavior with normal power-up | known-good clamp and holder | keep diagnosis in the current path | move to utility or output logic |
| weak top-end performance | stable utility source and known-good current path | keep diagnosis in utility or current path | move deeper only if the healthy source still fails |
| complaint starts after lead service or setup change | correct DCEN / DCEP lead placement for the actual rod test | keep diagnosis in setup and external current path | move deeper only if the arc is still wrong with correct polarity |
| hot clamp, holder, or plug | known-good heavy-duty current path | keep diagnosis external and mechanical | move to machine output only after heating path is proven |
| no useful output with healthy externals | hold known-good current path steady | keep diagnosis external if the complaint follows the leads | move to output branch only after external proof |
KAA20410: official product page07000460: official product page07000461: official product page