P40 Parts Substitution Card

This is the quick external-parts substitution card for the highest-value P40 torch-stack and air-path splits.

Use This Card When

Stage First

Fast Substitution Card

Complaint branch Swap first If the complaint follows the part... If the complaint stays with the machine...
no HF or weak HF fresh SG55 front-end stack and corrected striker gap keep diagnosis in the torch-start branch move to 24 V support and control logic only if the complaint remains
air but no cut or transfer known-good clamp and fresh torch stack keep diagnosis in clamp or torch-stack branch move into machine-side OCV and control branches
poor cut quality fresh 1.0 mm tip, electrode, nozzle with groove, and verified torch order keep diagnosis in the consumable and torch-order branch move deeper only if cut quality stays poor with a correct stack
air-path suspicion known-good dry air path, about 65 psi / 4.5 bar under flow, and cleared gas orifice keep diagnosis in the air branch move into electronics only after dry air is proven
starts are inconsistent after warm compressor cycles known-good dry air path and purge-style contamination check at about 1/8 in / 3 mm from clean metal keep diagnosis in wet-air or contamination branch move into electronics only if the gas stream stays clean

Official Ordering Shortcuts

Stop Rules