This is the quick external-parts substitution card for the highest-value CoolArc200 false-fault paths.
17V torch and regulator or flowmeter| Complaint branch | Swap first | If the complaint follows the part... | If the complaint stays with the machine... |
|---|---|---|---|
| weak output or no usable arc before internal proof | known-good clamp and lead path after confirming the real input and adapter path | keep diagnosis in the current path | move to J3 sense and OCV branch logic |
| blink-only or unstable startup with no real fan behavior | known-good fan branch | keep diagnosis in the fan or support branch | move to control and input-state diagnosis |
| TIG-only complaint | known-good official TIG kit and gas setup after stick baseline is proven | keep diagnosis in the kit, torch, or regulator path | move back to stick baseline and then the guide |
07003750: official product page07001825: official product page07000462: official product pageVRD, sleep behavior, or first-weld wake-up state instead of a part fault.