CoolArc200 Input-Sense Answer Key
Drill
Correct First Proof Step
- prove actual connected input voltage and mode state before treating low OCV as failure
Acceptable Document Order
- CoolArc200 measurement card
- CoolArc200 fault workflow router
- CoolArc200 board opening map only if J3 and state proof still leave a machine-side fault
Required Takeaways
J3 pins 2 and 7 are the clean split between input sense and control indication
VRD and first-weld wake-up behavior can make low OCV normal
- fan-start oddities should stay in the fan branch before deeper board calls
Failing Moves
- calling every low-OCV complaint a bad output section
- opening the machine before input and mode story are clean
- ignoring startup blink evidence
Passing Answer Summary
- A correct answer proves actual input and state first, uses J3 to separate the sense branch from the control branch, and only opens the machine if those checks still point to a real internal fault.