This is the fast internal opening map for P40 once torch-stack, clamp, and air-path causes are already bounded.
SG55 front-end stack is already fitted or ruled out65 psi / 4.5 bar under flow and the correct test point are already proven| Board or internal group | Open first when... | Key connector or checkpoint | Best local file to open first |
|---|---|---|---|
| HF branch | there is no HF or very weak HF after torch and gap proof | HF branch and 24 VDC support path to the start circuit |
B.067RM.418-C_HF.pdf |
| Control board and interlock path | HF appears present but there is no usable OCV or cut output | control-side interlocks and support signals | B.067RM.410-C_control.pdf |
| Main power section | fan voltage drifts, the machine blinks, or switch-power behavior looks wrong | main-power section separated from the HF and control boards | B.067RM.419-C_main.pdf and P40_电路图.png |
| Torch-stack confirmation | air flows but the machine still will not cut, or the complaint shifts with warm or wet air | front-end stack order, starter-cartridge movement, purge contamination check, and gas-orifice path | P40_parts_breakdown.pdf |