PulseWave200 Panel-State Instructor Guide
Drill
Use This Guide For
- teaching reset-state discipline on digital TIG platforms
- stopping trainees from confusing panel-state, remote-only, and AC-only complaints
Opening Prompt
- "A PulseWave200 shows all 8s after an arc event and TIG will not restart cleanly. What do you prove before you open it?"
What To Listen For First
- the trainee should say torch negative, base torch only, sane gas flow, and reset-state path first
- they should explicitly keep remote-only complaints outside the machine until bounded
Redirect Questions
- if they rush into HF hardware: "What would a correct base TIG setup look like first?"
- if they ignore the display clue: "What does all 8s suggest before a board is condemned?"
Strong Answer Markers
- they use the restore-default path before naming a failed board
- they separate AC-only failure from base TIG failure
- they keep remote and pedal complaints outside the machine until proven otherwise
Common Failure Modes
- jumping to HF-board suspicion before polarity or gas proof
- ignoring the panel-state clue because the machine still powers
- mixing remote-only, AC-only, and panel-state complaints into one vague diagnosis
Debrief Notes
- reinforce that state and accessory behavior are primary branches on this model, not cleanup work
- internal opening is justified only after reset-state, torch path, and remote path are already bounded