Job Packet / KickingHorse / M185

Packet use

Intake snapshot

Item Record
Serial or shop tag
Exact complaint
Display behavior on startup
Feed behavior at idle
Inductance setting as found
Source voltage and breaker path as found
Torch condition as found
Wire type and size as found
Arc behavior on first trigger

Likely parts and accessories to stage

Item Why stage it early
Known-good NT1-3E torch or equivalent torch baseline fastest way to remove torch-side false faults
Known-good clamp and lead set current-path issues still distort readout complaints
Fresh contact tips simple front-end wear can mimic a control fault
Stable 208/230 V source path matched to intended proof level needed before display or output blame
Meter and probes needed when display and feed complaints overlap

Official parts-entry shortcuts

First branch decisions

If you see... Stay in this branch first
No feed plus bad display display or control branch
Display wrong but weld still possible display feedback branch
Arc bad with normal display torch front-end, current path, inductance, and source branch
Starts improve after returning inductance to sane baseline setup branch first
Complaint appears only on weak source or wrong breaker path source branch first
Complaint follows torch swap external torch branch

Local files to open first

Bench workflow

  1. Capture display and feed behavior before opening the machine.
  2. Run M185 bench test.
  3. Prove one plain-steel baseline first on a real 208/230 V source with the intended breaker path.
  4. Return inductance to a sane known-good setting before deeper escalation.
  5. Retest the original branch only after torch and current path are clearly healthy.

Release signoff

Check Result
Stable startup restored pass / fail
Display behavior restored pass / fail
Base MIG baseline restored on correct source and sane inductance baseline pass / fail
No repeat no-feed, frozen-display, or source-path collapse complaint after power cycle pass / fail
Release ticket records proven display behavior and source path pass / fail
Covers, grounds, and lead routing restored pass / fail

Technician: __________ Date: __________