| Item | Record |
|---|---|
| Serial or shop tag | |
| Exact complaint | |
| Input source used by customer | |
| 110 V or 220 V branch tested in shop | |
| VRD mode expectation | |
| Plug, adapter, and receptacle condition | |
| Clamp and holder condition |
| Item | Why stage it early |
|---|---|
| Known-good plug or adapter path | source-path faults are common on voltage-class complaints |
| Known-good clamp and holder set | eliminates return-path false faults before board work |
| Meter leads for J3 testing | input-sense checks are central on this model |
| Simple TIG kit if package requires it | only after stick proving is complete |
07003750: official product page07001825: official product page07000462: official product page| If you see... | Stay in this branch first |
|---|---|
| J3 sense voltage wrong | main-board input-detect branch |
| Sense voltage correct but display wrong | control-board branch |
| Low OCV only in VRD behavior | normal state branch, not output failure |
| Blink-only display or no stable fan start | fan or support branch before control-board blame |
| Light and fan present but still no usable output | output or control branch after state logic is proven |
assets/reference_doc/WeldKing/CoolArc200assets/reference_doc/WeldKing/CoolArc200assets/reference_doc/WeldKing/CoolArc200| Check | Result |
|---|---|
| Correct voltage recognition proved | pass / fail |
| VRD or non-VRD behavior understood and normal | pass / fail |
| Stable output baseline restored | pass / fail |
| No heat at plug, adapter, clamp, or holder | pass / fail |
| Covers, grounds, and lead routing restored | pass / fail |
Technician: __________ Date: __________