A100 Measurement Card

This is the quick live-reading card for the highest-value A100 branch-power, OCV, and blinking-light splits.

Use This Card When

Prove First

Fast Measurement Card

Checkpoint Where to measure or observe Healthy expectation If abnormal, keep diagnosis in...
Input branch under attempted load at the machine input stays in a usable 120 V range on a 20 A branch or healthy 3 kW generator baseline utility path
OCV at output studs output studs with the machine healthy about mid-80 V class OCV output or IGBT branch
Rectifier DC when the machine appears dead rectifier side in the dead-machine split present if switch or low-voltage supply is the real fault switch or low-voltage supply branch
Power light and fan state live observation on power-up steady normal operation, not slow blinking collapse fan or support-power branch
Yellow protection light during short proof weld live observation during 7018 or 6010/6011 test stays off in normal short proof welds airflow, fan, or source-strength branch
Stock holder and clamp heat after a short proof weld on the fitted lead set no rapid abnormal heat in the 5 ft AWG #6 stock lead path external current path