This is the quick live-reading card for the highest-value A100 branch-power, OCV, and blinking-light splits.
| Checkpoint | Where to measure or observe | Healthy expectation | If abnormal, keep diagnosis in... |
|---|---|---|---|
| Input branch under attempted load | at the machine input | stays in a usable 120 V range on a 20 A branch or healthy 3 kW generator baseline | utility path |
| OCV at output studs | output studs with the machine healthy | about mid-80 V class OCV | output or IGBT branch |
| Rectifier DC when the machine appears dead | rectifier side in the dead-machine split | present if switch or low-voltage supply is the real fault | switch or low-voltage supply branch |
| Power light and fan state | live observation on power-up | steady normal operation, not slow blinking collapse | fan or support-power branch |
| Yellow protection light during short proof weld | live observation during 7018 or 6010/6011 test | stays off in normal short proof welds | airflow, fan, or source-strength branch |
| Stock holder and clamp heat | after a short proof weld on the fitted lead set | no rapid abnormal heat in the 5 ft AWG #6 stock lead path | external current path |