This is the quick live-reading card for the highest-value CoolCut30 24 V, OCV, and start-branch splits.
| Checkpoint | Where to measure or observe | Healthy expectation | If abnormal, keep diagnosis in... |
|---|---|---|---|
| Upper-board green 24 V indicator | upper board during power-up and start attempt | stays on continuously when support power is healthy | capacitor-board or upper-board support branch |
| Fan behavior | fan during power-up and start attempt | stable and not collapsing when the board branch is loaded | support-power branch |
| OCV behavior | output during start attempt | clearly high, low, or absent and repeatable | relay, capacitor-board, or inverter branch |
| HF behavior | audible or visible HF at start attempt | consistent HF on clean steel | HF gap, relay, or upper-board branch |