CoolCut30 Measurement Card

This is the quick live-reading card for the highest-value CoolCut30 24 V, OCV, and start-branch splits.

Use This Card When

Prove First

Fast Measurement Card

Checkpoint Where to measure or observe Healthy expectation If abnormal, keep diagnosis in...
Upper-board green 24 V indicator upper board during power-up and start attempt stays on continuously when support power is healthy capacitor-board or upper-board support branch
Fan behavior fan during power-up and start attempt stable and not collapsing when the board branch is loaded support-power branch
OCV behavior output during start attempt clearly high, low, or absent and repeatable relay, capacitor-board, or inverter branch
HF behavior audible or visible HF at start attempt consistent HF on clean steel HF gap, relay, or upper-board branch

Official Parts Shortcuts

Stop Rules

Open Next