This is the quick external-parts substitution card for the highest-value A100 clamp, holder, and utility-path splits.
| Complaint branch | Swap first | If the complaint follows the part... | If the complaint stays with the machine... |
|---|---|---|---|
| weak arc or hard start | known-good clamp and holder | keep diagnosis in the current path | move to OCV and support logic |
| complaint changes with outlet quality | stable utility source | keep diagnosis in the utility path | move deeper only if stable power still fails |
| complaint starts after lead service or setup change | correct DCEN / DCEP lead placement for the actual rod test | keep diagnosis in setup and external current path | move deeper only if the arc is still wrong with correct polarity |
| blinking-light collapse with healthy externals | keep external parts fixed and retest | keep diagnosis in support-power or fan branch | move deeper only after the external path is clean |
| no output with otherwise healthy setup | hold known-good current path steady | keep diagnosis external if the complaint follows the lead set | move to output or IGBT branch only after external proof |