This is the quick external-parts substitution card for the highest-value PulseWave200 TIG accessory and control-path splits.
FC25-HD, FC25-WL, or YK25-WL| Complaint branch | Swap first | If the complaint follows the part... | If the complaint stays with the machine... |
|---|---|---|---|
| no TIG start with a torch or remote connected | known-good base TIG torch on negative with no optional control branch and simple DC TIG baseline | keep diagnosis in the torch or connected accessory | move to stored-state, gas-flow, and AC/DC branch logic |
| complaint exists only with one pedal or remote | known-good single control device, one at a time | keep diagnosis in that remote branch | move into the main machine only if local or base-torch operation still fails |
| unstable low-current start | corrected gas setup and known-good torch front end | keep diagnosis in gas or torch path | move deeper only if the basic TIG baseline still fails |
WAT31100: official product page07002510: official product page07002515: official product page