Job Packet / KickingHorse / A100

Packet use

Intake snapshot

Item Record
Serial or shop tag
Exact complaint
Input source as found
Breaker rating and cord length as found
Clamp and holder condition on arrival
Lead polarity as found
Power-light and fan behavior on arrival
OCV reading if already checked

Likely parts and accessories to stage

Item Why stage it early
Known-good heavy-duty clamp fastest way to remove current-path false faults
Known-good holder branch separates holder wear from machine output loss
Meter for branch and OCV checks needed for the dead-machine split
Simple dry 3/32 in 7018 or 6010/6011 rods keeps the baseline clean and repeatable
Known-good 20 A source or healthy 3 kW generator path proves the machine on its official power baseline

Official parts-entry shortcuts

First branch decisions

If you see... Stay in this branch first
Dead machine but rectifier DC present switch or low-voltage supply branch
No OCV with healthy upstream DC output or IGBT branch
Blinking power light or fan collapse fan and support-power branch
Better clamp or outlet changes the complaint current path or utility path
Arc is wrong only after lead service or setup change polarity and external current-path branch
Complaint only exists on improvised TIG use stop there because the machine is officially stick-only

Local files to open first

Bench workflow

  1. Normalize input source, breaker, extension-cord path, clamp, holder, and polarity.
  2. Run A100 bench test.
  3. Separate dead-machine, no-OCV, wrong-polarity, and blinking-light complaints.
  4. Re-power retest after correction.

Release signoff

Check Result
OCV restored pass / fail
3/32 in rod baseline restored pass / fail
No abnormal heating, protection light, or blink-state collapse pass / fail
Covers, grounds, and lead routing restored pass / fail

Technician: __________ Date: __________