| Item | Record |
|---|---|
| Serial or shop tag | |
| Exact complaint | |
| No start, no HF, pilot-only, or no-transfer complaint | |
| Air source and pressure-under-flow state | |
| Clamp placement on arrival | |
| Torch front-end condition | |
| Fan and 24 V indicator behavior |
| Item | Why stage it early |
|---|---|
| Fresh SG55 front-end stack | fastest way to remove front-end false faults |
| Known-good clamp and clean steel coupon | transfer complaints stay return-path heavy |
| Dry air source | wet air creates repeated false machine faults |
| Meter and insulated probes | needed for 24 V, fan, and OCV branch checks |
07Y2517003: official product page07Y2517005: official product page07Y2517004: official product page| If you see... | Stay in this branch first |
|---|---|
| No HF with high OCV | relay or capacitor-board branch |
| No HF with lower OCV | upper-board or inverter branch |
| Green 24 V light drops or fan collapses | support-power branch |
| Pilot but no transfer | torch front-end, clamp, and air branch |
| Fan or 24 V instability | support-power branch |
assets/reference_doc/WeldKing/CoolCut30/CoolCut30_service_manual.pdfassets/reference_doc/WeldKing/CoolCut30/COOLCUT30 AND STICK160.docCoolCut30 in assets/reference_doc/all_models/troubleshoot_notes.xlsx| Check | Result |
|---|---|
| Green 24 V indicator remains stable | pass / fail |
| Stable start restored | pass / fail |
| Stable transfer restored | pass / fail |
| Short cut completed cleanly | pass / fail |
| Covers, grounds, and lead routing restored | pass / fail |
Technician: __________ Date: __________