Job Packet / WeldKing / PulseWave200

Packet use

Intake snapshot

Item Record
Serial or shop tag
Exact complaint
DC TIG, AC TIG, or both affected
Torch polarity as found
Remote, pedal, or torch-switch path in use
Gas setup and flow state
Display behavior on power-up

Likely parts and accessories to stage

Item Why stage it early
Known-good TIG torch and tungsten removes common torch-side false faults
Known-good gas regulator and hose path low-current and start complaints are often gas-path related
Remote or pedal only if the complaint involves it avoids mixing remote faults into a base-machine test
Meter for low-current proving and state checks needed when the complaint is subtle rather than total failure

Official parts-entry shortcuts

First branch decisions

If you see... Stay in this branch first
All 8s or frozen display reset-state and display branch
No HF with otherwise basic setup incomplete polarity, torch, and gas branch first
DC TIG good but AC TIG dead AC-mode branch, not whole-machine failure
Low-current TIG unstable gas path and control-state branch before power-stage suspicion

Local files to open first

Bench workflow

  1. Normalize torch polarity, gas path, and control mode.
  2. Run PulseWave200 bench test.
  3. Prove DC TIG first.
  4. Prove AC TIG only after DC TIG is clearly healthy.

Release signoff

Check Result
Normal display state on cold start pass / fail
DC TIG baseline restored pass / fail
AC TIG baseline restored if required pass / fail
Gas path stable and no abnormal retained fault state pass / fail
Covers, grounds, and lead routing restored pass / fail

Technician: __________ Date: __________