Job Packet / WeldKing / TIG200PACDC

Packet use

Intake snapshot

Item Record
Serial or shop tag
Exact complaint
DC TIG, AC TIG, or both affected
Pedal or remote path in use
Gas setup and flow state
Stick branch behavior if tested

Likely parts and accessories to stage

Item Why stage it early
Known-good TIG torch and tungsten removes common torch-side false faults
Known-good gas regulator and hose path shielding complaints still dominate these machines
Known-good pedal only if the complaint involves it avoids mixing remote faults into the base-machine test
Meter for mode and response checks needed when the complaint is AC/DC-state specific

Official parts-entry shortcuts

First branch decisions

If you see... Stay in this branch first
DC TIG healthy but AC TIG unstable AC-mode branch
Complaint follows one pedal only remote or pedal branch
Gas-flow complaint changes immediately with setup correction gas branch
Stick healthy while TIG stays dead TIG-only branch

Local files to open first

Bench workflow

  1. Normalize gas path, confirm the pedal branch if used is the correct 4K7 family, and simplify to DC TIG.
  2. Run TIG200PACDC bench test.
  3. Prove AC TIG only after DC is healthy.
  4. Add pedal proving only if the base machine is already stable.

Release signoff

Check Result
DC TIG baseline restored pass / fail
AC TIG baseline restored if required pass / fail
Correct pedal or remote response proved if required pass / fail
Pedal or remote branch proven healthy if required pass / fail
Covers, grounds, and lead routing restored pass / fail

Technician: __________ Date: __________