| Item | Record |
|---|---|
| Serial or shop tag | |
| Exact complaint | |
| DC TIG, AC TIG, or both affected | |
| Pedal or remote path in use | |
| Gas setup and flow state | |
| Stick branch behavior if tested |
| Item | Why stage it early |
|---|---|
| Known-good TIG torch and tungsten | removes common torch-side false faults |
| Known-good gas regulator and hose path | shielding complaints still dominate these machines |
| Known-good pedal only if the complaint involves it | avoids mixing remote faults into the base-machine test |
| Meter for mode and response checks | needed when the complaint is AC/DC-state specific |
07000510: use the official parts category above.072611120: use the official parts category above.| If you see... | Stay in this branch first |
|---|---|
| DC TIG healthy but AC TIG unstable | AC-mode branch |
| Complaint follows one pedal only | remote or pedal branch |
| Gas-flow complaint changes immediately with setup correction | gas branch |
| Stick healthy while TIG stays dead | TIG-only branch |
assets/reference_doc/WeldKing/TIG200PACDC/TIG200PACDCmanualsimple version.pdfTIG200PACDC in assets/reference_doc/all_models/troubleshoot_notes.xlsx| Check | Result |
|---|---|
| DC TIG baseline restored | pass / fail |
| AC TIG baseline restored if required | pass / fail |
| Correct pedal or remote response proved if required | pass / fail |
| Pedal or remote branch proven healthy if required | pass / fail |
| Covers, grounds, and lead routing restored | pass / fail |
Technician: __________ Date: __________