KickingHorse Symptom-To-Model Chooser

This page helps technicians identify likely KickingHorse model families when labels are missing, the incoming machine has mismatched accessories, or the paperwork is incomplete.

How to Use This Chooser

Fast Identification Table

Visible clue or incoming complaint Likely model or family Confirmation clues Open first
small 120 V stick inverter with simple one-knob control and about 100 A class behavior A100 simple DC stick only platform, OCV around the mid-80 V range, small-machine current-path complaints A100 guide
larger 208 or 230 V class stick inverter with about 220 A output and stronger field-power positioning A220 bigger input expectations, higher-output stick work, stronger generator and branch-power focus A220 guide
compact 120 V flux-core machine with left-hand-thread seat detail at the torch front end F130 flux-core-only style complaints, trigger-state voltage split, front-end thread detail F130 guide
MIG or FCAW machine with digital preset display where feed and display faults can appear together M185 digital A/V display behavior is the giveaway M185 guide
multiprocess machine with MIG, stick, lift-TIG, optional aluminum kit, and process-button behavior MA200TS one-second shutdown, wire feed at power-up, maxed display, and package-specific kit options MA200TS guide
plasma machine with SG55 torch, HF start, and compact 40 A class complaints P40 no HF, HF but no OCV, and front-end stack complaints on one compact plasma platform P40 guide

Identification shortcuts

If you can confirm... That usually means...
simple stick-only machine on 120 V A100
stick-only machine but clearly larger 230 V class A220
flux-core-only machine with compact front-end details and no multiprocess path F130
digital preset MIG or FCAW machine with display-led behavior M185
optional aluminum or TIG kit on one base machine MA200TS
SG55 torch and compact plasma branch P40

When two models still look possible

Best follow-on references