This router gives the fastest document order for the highest-value PulseWave200 complaints.
| Incoming complaint | Open first | Then open | Then open if the complaint remains | Why this order works |
|---|---|---|---|---|
| all 8s on the display or panel-state corruption after arc strike | PulseWave200 measurement card | PulseWave200 board opening map | PulseWave200 guide | the restore-default path is the fastest proof, then the opening map keeps the internal work inside the display-state branch |
| TIG will not start | PulseWave200 measurement card | PulseWave200 parts substitution card | PulseWave200 board opening map | polarity, simple DC TIG, and gas must be bounded first, then torch or remote, and only then the internal control branch |
| DC TIG works but AC TIG does not | PulseWave200 measurement card | PulseWave200 board opening map | PulseWave200 guide | this is the cleanest route into the AC-only branch without getting lost in the base TIG setup |
| complaint follows only one pedal or remote | PulseWave200 parts substitution card | PulseWave200 guide | PulseWave200 board opening map | remote-only complaints should stay out of internal repair until the control device is bounded |
WAT31100: official product page07002510: official product page07002515: official product page