This router gives the fastest document order for the highest-value CoolCut30 complaints.
| Incoming complaint | Open first | Then open | Then open if the complaint remains | Why this order works |
|---|---|---|---|---|
| no HF with high OCV | CoolCut30 measurement card | CoolCut30 board opening map | CoolCut30 job packet | the OCV split points the work toward relay and support branches immediately, so the machine should not be treated like a low-OCV case |
| no HF with lower OCV | CoolCut30 measurement card | CoolCut30 board opening map | CoolCut30 guide | low-OCV no-HF belongs in the upper-board or inverter branch and should not be mixed with the high-OCV relay path |
| pilot exists but there is no transfer | CoolCut30 parts substitution card | CoolCut30 guide | CoolCut30 job packet | transfer complaints stay on clamp, air, and front-end proving first |
| fan or 24 V behavior is unstable | CoolCut30 measurement card | CoolCut30 board opening map | CoolCut30 job packet | support-power proof comes before general output-board blame |