KickingHorse Shop Wall Chart

This is the short printable KickingHorse triage poster for fast bench intake and first-proof routing.

How to Use This Chart

Complaint Families

Complaint family First proof step Open first Open next if still unresolved
A100 unstable stick output, blinking power light, or collapse on a 120 V portable stick machine prove real 120 V / 20 A or healthy 3 kW, correct DCEN / DCEP, clean-steel 3/32 in 7018 or 6010/6011 baseline, and basic OCV first A100 measurement card A100 fault workflow router
A220 weak top-end stick output, bad arc blow, or poor rod behavior on a 208/230 V field machine prove real 208/230 V, ideally 50 A or healthy 5 kW, correct DCEN / DCEP, clean-steel 7018 or 6010/6011 baseline, and basic OCV first A220 measurement card A220 fault workflow router
wire feeds at power-up, one-second shutdown, maxed display, or stick works but MIG does not prove one healthy process first, set drive pressure correctly, verify feed does not move at power-up, and confirm the display tracks the active process MA200TS measurement card MA200TS fault workflow router
compact MIG no feed, higher-wire-speed start trouble, breaker trip, or torch-front-end suspicion return to factory 0.035 in baseline or proper 0.030 in conversion, then prove bare-wire feed and 12 VDC to 44 VDC trigger-state rise on a real 120 V / 20 A or 3 kW source F130 measurement card F130 fault workflow router
wrong MIG display, feed and display wrong together, or shared digital weirdness prove real 208/230 V source, reset inductance to sane baseline, and confirm preset-versus-actual display behavior before blaming power hardware M185 measurement card M185 fault workflow router
no HF, HF but no OCV, air but no cut, or warm drift on plasma prove fresh SG55 stack, clean clamp, dry air under flow near 65 psi / 4.5 bar, about 1.5 mm HF gap, 24 VDC to the HF board, and the correct OCV test point first P40 measurement card P40 fault workflow router

Stop Before Internal Repair When

Fast Official Parts Exits

Best Companion Docs