This page pulls the fastest bench-useful WeldKing measurements and state checks into one place so technicians can compare live readings without scanning every model guide first.
VRD, sleep behavior, or first-weld wake-up behavior can make low OCV normal on some platforms.| Model | Checkpoint | Healthy expectation | If abnormal, keep diagnosis in... | Open next |
|---|---|---|---|---|
CoolArc160 |
CN101 high-voltage bus from capacitor PCB to inverter PCB |
roughly 300 to 340 VDC on a healthy high-line machine |
capacitor PCB or primary-rectifier branch if bus is low with correct input power | CoolArc160 guide |
CoolArc160 |
CN108 or CN104 fan connector depending on board revision |
24 VDC auxiliary supply present with the correct polarity for the fitted revision |
capacitor-board support path and early fan-polarity revision branch | CoolArc160 guide |
CoolArc160 |
OCV with healthy bus already proven | healthy OCV and normal arc strike; low OCV around the 30 V range with healthy bus is not normal |
capacitor PCB first if low OCV remains with healthy bus; inverter PCB if no OCV with healthy bus | CoolArc160 bench test |
CoolArc200 |
J3 pins 2 and 7 on the input-sense branch |
about 3.3 V on 110 V input and about 0.3 V on 220 V input |
main-board input-detect or control-board indication branch | CoolArc200 guide |
CoolArc200 |
OCV in non-VRD mode |
low immediately after power-up can recover to normal high OCV after the first weld | sleep-state or mode-state interpretation before output-board repair | CoolArc200 guide |
CoolArc200 |
OCV in VRD mode |
stays at a low safe-voltage level by design | state interpretation and VRD behavior, not the welding section by itself |
CoolArc200 guide |
| Model | Checkpoint | Healthy expectation | If abnormal, keep diagnosis in... | Open next |
|---|---|---|---|---|
MAG211 |
gas-solenoid branch | about 36 VAC at the solenoid branch when the weld command is active |
solenoid or control branch before deeper transformer diagnosis | MAG211 measurement card |
MAG211 |
voltage and wire-speed chart baseline | actual behavior tracks the official chart closely enough to produce a stable weld | setup or chart mismatch before internal repair | MAG211 measurement card |
MAG211 |
base gun versus spool gun | base MIG proves first and the complaint stays isolated if it really belongs to the spool-gun branch | spool-gun and drive-roll branch before transformer or board blame | MAG211 measurement card |
MAG251 |
gas-solenoid branch | about 36 VAC when the machine is commanding gas flow |
solenoid or control branch before calling the whole machine dead | MAG251 measurement card |
MAG251 |
AC ripple at the output | about 1 VAC healthy; roughly 6 to 7 VAC points toward capacitor trouble |
capacitor-bank condition first | MAG251 measurement card |
MAG251 |
feed direction after PCB or motor work | motor feeds in the correct direction with no breaker drama | motor wiring or post-service branch before replacement-board blame | MAG251 measurement card |
MAG255 |
spool-gun pins 1 and 9 when spool-gun mode is selected |
welding voltage present on the selected spool-gun branch | spool-gun selector or accessory branch before transformer calls | MAG255 measurement card |
MAG255 |
post-trigger discharge behavior | capacitor discharges cleanly and wire stops without abnormal creep | crater-fill or discharge-path branch if wire creeps after stop | MAG255 measurement card |
MAG255 |
wire-tip behavior with no trigger command | no sparks or unexpected live-wire behavior at the tip | discharge-path resistor branch before control-board suspicion | MAG255 measurement card |
MigSonic145 |
24 V support branch |
stable auxiliary voltage without click-cycling | capacitor PCB and support-power branch | MigSonic145 measurement card |
MigSonic145 |
trigger response after 24 V is proven |
machine responds normally to the gun trigger | trigger-wire or control branch, not the whole power source | MigSonic145 measurement card |
MigSonic145 |
base-gun bare-wire feed with the contact tip removed | wire feeds normally on the base gun without a spool gun attached or a tip load masking the branch | gun-generation, drive, or trigger branch before deeper PCB blame | MigSonic145 measurement card |
MigSonic145 |
startup click-cycling or post-capacitor feed behavior | stable startup with no repeated relay click and no runaway motor | support-power or control PCB branch before gun blame | MigSonic145 measurement card |
MigSonic252S+SS20 |
feeder and readout response from the power source | commands from the power source are reflected at the remote feeder without frozen readouts or a solenoid stuck open at idle | power-source PCB branch rather than the remote feeder itself | MigSonic252S+SS20 measurement card |
MigSonic252S+SS20 |
solenoid or readout state at power-up | gas stays closed until commanded and readouts behave normally | source-side PCB branch before feeder blame | MigSonic252S+SS20 measurement card |
MigSonic252S+SS20 |
source-side jog or purge behavior before feeder teardown | source commands behave normally before the remote package is blamed | source-side PCB or control-state branch before feeder-package teardown | MigSonic252S+SS20 measurement card |
| Model | Checkpoint | Healthy expectation | If abnormal, keep diagnosis in... | Open next |
|---|---|---|---|---|
MigSonic200 CVCC |
main bus voltage after input and rectifier proof | normal bus behavior rather than a persistent mid-100 V reading after board work |
rectifier branch before process guessing | MigSonic200 CVCC guide |
MigSonic200 CVCC |
trigger response after 24 V support is proven |
gun trigger produces a real response in the active branch | broken trigger wire or control branch | MigSonic200 CVCC guide |
MultiSonic220 |
startup state after reset | machine exits debug behavior and boots normally after the documented reset sequence | stored-state, ribbon, or support-power branch | MultiSonic220 guide |
MultiSonic220 |
polarity connector when stick and TIG still work but MIG does not | tight and correctly installed for the active process | polarity and MIG-only current-path branch | MultiSonic220 guide |
MultiSonic220 |
panel behavior on power-up | stable display and indicators, not all-lights flashing | ribbon, control, or power-supply branch | MultiSonic220 bench test |
MultiSonic220 |
feeder motor at idle | stopped until a real feed command is given | power board or support-power branch if motor runs full speed at power-up | MultiSonic220 guide |
| Model | Checkpoint | Healthy expectation | If abnormal, keep diagnosis in... | Open next |
|---|---|---|---|---|
CoolTIG220 |
basic DC TIG baseline | stable start, normal preflow and postflow, and a clean local-control branch | gas path, torch branch, or package-state branch before AC or HF repair | CoolTIG220 guide |
CoolTIG220 |
HF-versus-no-HF version proof | behavior matches the documented version note before any HF complaint is trusted | wrong version assumption before board repair | CoolTIG220 guide |
CoolTIG220 |
remote or torch-switch branch | control changes only when the correct switch or pedal branch is active | pedal, torch-switch, or package-state branch before control-board repair | CoolTIG220 guide |
PulseWave200 |
torch polarity for HF start | torch on negative for TIG start | torch-path setup before any HF-board call | PulseWave200 guide |
PulseWave200 |
display PCB switch 2 reset on later machines |
factory defaults restore when the switch is used with power off and the machine restarts | stored-state or display-state branch | PulseWave200 bench test |
PulseWave200 |
gas flow at very low current | moderate flow with preflow reduced as needed for low-current work | gas-path setup before blaming a dead HF branch | PulseWave200 guide |
PulseWave200 |
AC versus DC TIG branch | both operate once the base machine is healthy | AC inverter section if DC works but AC does not | PulseWave200 guide |
TIG200PACDC |
simple DC TIG baseline before AC | repeatable DC TIG start on clean steel before AC is added back | gas, torch, or TIG-only branch before AC-board suspicion | TIG200PACDC measurement card |
TIG200PACDC |
local-control baseline with the remote isolated | panel control behaves normally before the pedal branch is trusted | remote, pedal, or local-control branch before AC-board repair | TIG200PACDC measurement card |
TIG200PACDC |
foot-control or current remote potentiometer | correct 4K7 resistance value for the fitted remote |
pedal or remote branch before control-board repair | TIG200PACDC measurement card |
| Model | Checkpoint | Healthy expectation | If abnormal, keep diagnosis in... | Open next |
|---|---|---|---|---|
CoolCut30 |
upper-board green 24 V indicator |
stays on continuously when the support rail is healthy | capacitor-board versus upper-board supply split | CoolCut30 guide |
CoolCut30 |
no-HF with OCV already measured | no-HF with OCV in the high 200 V range stays in the lower-board relay or capacitor-board branch; lower OCV points toward the inverter or top board |
the board family matched to the OCV level | WeldKing reference manifest |
CoolCut30 |
HF strike gap | about 1 mm |
HF-striker cleanliness and gap before deeper plasma-board work | CoolCut30 guide |
CoolCut40air |
built-in compressor and dual-valve air path | steady airflow under trigger with no obvious pressure collapse | compressor, valve, or air-routing branch before output-board suspicion | CoolCut40air measurement card |
CoolCut40air |
internal versus external air mode split | complaint is bounded to one air mode or behaves correctly in both with the right path active | internal-air valve contamination or mode-routing branch before board calls | CoolCut40air measurement card |
CUT40 |
external-air behavior under flow | clean, stable air delivery without wet-air contamination or unstable torch behavior | regulator, hose, filter, or CB50 front-end branch | CUT40 measurement card |
CUT40 |
guide-hardware versus freehand behavior | freehand cutting stays healthy and guide hardware does not create the complaint | guide or CB50 hardware branch before board blame | CUT40 measurement card |
CUT65 |
pilot behavior relative to pressure and RV1 |
pilot and transfer stay stable without extreme pressure tuning | air-pressure branch or pilot-maintain-current setting before PCB replacement | CUT65 measurement card |
CUT65 |
torch-head rebound and postflow no-start split | torch head returns correctly and start is not lost after normal postflow | torch-head or A81 hardware branch before PCB blame | CUT65 measurement card |
CUT65 |
freehand cut versus A81 hardware behavior | freehand cutting stays healthy before stand-off or circle-kit blame | A81 hardware branch before PCB blame | CUT65 measurement card |
ThunderCut65 |
postflow, restrike, and pilot-maintain-current behavior | repeatable restrike without abnormal wait time or constant pressure chasing | air path, torch mechanics, or RV1 pilot branch |
ThunderCut65 guide |
ThunderCut65 |
pressure-window or RV1 response |
start and pilot improve without extreme tuning once the correct pressure window is reached | air path or pilot-maintain-current branch before PCB replacement | ThunderCut65 guide |
ThunderCut65 |
torch-head and guide-hardware behavior | torch head returns correctly and tracking hardware does not distort the complaint | torch-head rebound, guide carriage, or stand-off branch before electrical fault calls | ThunderCut65 guide |
CoolArc160, CoolArc200, MAG251, MAG255, MultiSonic220, PulseWave200, and CoolCut30, while MAG211, CoolTIG220, CoolCut40air, and ThunderCut65 rely on strong behavior-plus-measurement splits.MAG211, MAG251, and MAG255 now route directly from this reference into their model-specific measurement cards, so the MAG family no longer has to be entered through one shared placeholder.MigSonic145, MigSonic252S+SS20, TIG200PACDC, CoolCut40air, CUT40, and CUT65 now route directly from this reference into their model-specific measurement cards too.