This is the print-ready KickingHorse shop workflow bundle. Use it when the machine is in the KickingHorse family and you want one packet to route the job from intake to release.
| Incoming model | Start here | Bench test |
|---|---|---|
| A100 | job packet | bench sheet |
| A220 | job packet | bench sheet |
| F130 | job packet | bench sheet |
| MA200TS | job packet | bench sheet |
| M185 | job packet | bench sheet |
| P40 | job packet | bench sheet |
A100: prove a real 120 V / 20 A branch first, or a healthy 3 kW non-inverter generator path, before treating weak output, hard starts, or collapse as internal failure.A100: prove correct DCEN / DCEP lead placement for the actual rod test before swapping boards, leads, or controls.A100: prove a supported stick baseline with clean steel and 3/32 in 7018 or 6010/6011 before any internal escalation.A100: if the complaint only exists on an improvised TIG setup, stop there because that is not a supported process path for this machine.A220: prove a real 208/230 V source first and use an ideally 50 A branch or healthy 5 kW generator path before treating top-end weakness as internal failure.A220: prove correct DCEN / DCEP lead placement and a healthy current path before treating spatter, bad arc blow, or weak rod behavior as inverter failure.A220: prove a supported stick baseline with clean steel and 7018 or 6010/6011 before opening the machine.A220: if the complaint only exists on an improvised TIG setup, stop there because that is not a supported process path for this machine.F130: return the machine to factory 0.035 in flux-core baseline first, or prove a proper 0.030 in conversion before any deeper teardown.F130: do not treat 0.023 in wire, DCEP wire expectations, a weak branch, or a non-compliant extension-cord path as internal evidence.M185: prove a real 208/230 V source first, and respect the manual 40 A normal or 50 A time-delay breaker guidance for rated-output proof.M185: reset inductance to a sane baseline and confirm preset-versus-actual display behavior before treating the display PCB as the lead suspect.MA200TS: prove one healthy baseline process first, then retest the failing process so a MIG-only or TIG-only complaint does not get misread as a whole-machine failure.MA200TS: if the unit powers up for one second and shuts down, keep wall-power quality, switch path, support-power board behavior, and loose motor or feedback wiring in play before main-inverter blame.MA200TS: if one process is healthy, keep the diagnosis in process state, accessory path, polarity, feedback cable, or process-button branch first.P40: prove dry air under flow, about 65 psi / 4.5 bar minimum, a fresh SG55 front-end stack, and clean clamp placement before any control-board or HF-board call.P40: verify the HF gap at about 1.5 mm, confirm the HF board sees about 24 VDC, and check OCV only at the correct machine-output point with the HF wire unplugged.A100: only after correct polarity and a supported stick baseline are proven, use accessories path, ground clamp 07000461, holder 07000460A220: only after correct polarity and a supported stick baseline are proven, use accessories path, ground clamp 07000461, holder 07000460F130: accessories path, contact tip KOM32135, product pageMA200TS: accessories path, aluminum kit XOM99035, product pageM185: product page, torch KAM31003, contact tip KOM32135P40: accessories path, electrode 07Y2517003, owner manualA100 clears on better 120 V / 20 A power, a healthy 3 kW generator path, corrected DCEN / DCEP, or abandoning an improvised TIG complaintA220 clears on a real 208/230 V source, a better branch or generator path, corrected DCEN / DCEP, heavier external current path, or abandoning an improvised TIG complaintF130 clears on correct wire-size setup, proper front-end hardware, or a real 120 V / 20 A or 3 kW sourceM185 clears on sane inductance, correct breaker path, or a stronger 208/230 V sourceMA200TS clears when the machine is simplified to one healthy process, the correct polarity path, and the right accessory kitP40 clears with a fresh SG55 stack, dry air, correct pressure, clean clamp, or correct HF-gap setup| Item | Record |
|---|---|
| Model and serial | |
| Exact complaint | |
| Failing process or stage | |
| Input source and branch quality | |
| Wire size, inductance, or display state as found | |
| Air pressure, polarity, or active kit state as found | |
| Accessory or kit package | |
| Clamp, torch, or front-end condition on arrival | |
| Display, feed, HF, or startup behavior on arrival | |
| Local reference folder used |
| Step | Observation or measurement | Branch kept alive | Next action |
|---|---|---|---|
| 1 | |||
| 2 | |||
| 3 | |||
| 4 | |||
| 5 |
| Item used | Part number or source | Why it was used | Installed yes / no |
|---|---|---|---|
| 1 | |||
| 2 | |||
| 3 | |||
| 4 |
| Check | Result |
|---|---|
| Baseline process or cut restored | pass / fail |
| Original complaint path repeated | pass / fail |
| Warm retest completed | pass / fail |
| No abnormal feed, display, HF, or supply drift | pass / fail |
| Correct source and setup baseline documented on release | pass / fail |
| Check | Result |
|---|---|
| Machine closed and hardware secure | pass / fail |
| Correct accessory package returned | pass / fail |
| Customer-facing notes captured | pass / fail |
| Final disposition recorded | pass / fail |
Technician: __________ Date: __________